BMS Communication Cables with Solar Inverters & Voltacon Lithium Ion Li-2021 2.4kWh and US2000 Pylontech

How Can We Help?

BMS Communication Cables with Solar Inverters & Voltacon Lithium Ion Li-2021 2.4kWh and US2000 Pylontech

Table 1 , contains the pin layout for the most used solar off grid inverters. The Battery port RS485 (RJ45 port) is located on the lithium ion battery Li-2021. Only 2 pin are required for the BMS communication protocol

PinNumber Battery RS485 BatteryCAN DEYE Victron Voltronic GOODWE  Growatt
1 B B A
2 A B
3 A H
4 L B H H
5 A L L
6 GND
7 A H
8 B L GND

 

Voltacon Batteery Li2021 (50Ah)  and Li2022 (100Ah)

BMS communication port on lithium ion batteries

 

US2000 & US3000 BMS Cable from Voltronic Inverter to Pylontech Batteries

 

Voltronic special BMS cable for Pylontech batteries

 

 

BMS Communication Port on Hybrid Inverters (Infinisolar & Voltasol)

 

The following image illustrates the pins used on hybrid inverters made by Voltronic. When US2000 & US3000 Pylontech batteries are connected to the inverter the Pin 4 and 5 will are in use.

BMS Box RJ45 Communication Port

 

 

 

Menu settings for Li-2021 Voltacon Batteries

Conversol off grid inverter menu for lithium ion batteries

 

Third party lithium ion battery connection

 

Axpert, Conversol , King and V5 off grid inverter

BMS Communication port for Axpert, Conversol off grid inverters, serial port with pin 3 and 5

 

For Hybrid inverter Infinisolar and Voltacon, refer to the online PDF file here