In this brief article we put together the key characteristics of two very popular solar inverters / chargers. The Conversol MKS II (2nd generation) is compared with the VMII 5kW off-grid inverter. Both devices output a pure sinewave voltage of 230VAC with selectable charging current from 10Amp to 80Amp. Voltacon integrated the latest MPPT algorithm on each unit with 99% efficiency. Technically that means a more accurate tracking of the PV power at any time with minium loss of power less than 1%.
MODEL | Conversol MKS II 5000-48 | Conversol VM II 5000-48 |
Rated Power | 5000VA/5000W | 5000VA/5000W |
Part No | 0610877900831 | 0610877900916 |
Parallel Capability | YES, 9 units | No |
Parallel Part Number | 31-010245-00G | N/A |
Antitrust-Kit | No | YES |
INPUT | ||
Voltage | 230 VAC | 230 VAC |
Selectable Voltage Range | 170-280 VAC (For Personal Computers) | 170-280 VAC (For Personal Computers) |
90-280 VAC (For Home Appliances) | 90-280 VAC (For Home Appliances) | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) | 50 Hz/60 Hz (Auto sensing) |
OUTPUT | ||
AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | 230VAC ± 5% |
Overload capacity | 5s@≥150% load; 10s@110%~150% load; 100ms @ ≥200% load |
5s@≥150% load; 10s@110%~150% load; 100ms @ ≥200% load |
Efficiency (Peak) | 90% | 90% |
Transfer Time | 10 ms (For Personal Computers) 20 ms (For Home Appliances) |
10 ms (For Personal Computers) 20 ms (For Home Appliances) |
Waveform | Pure sine wave | Pure sine wave |
BATTERY | ||
Battery Voltage | 48 VDC | 48 VDC |
Floating Charge Voltage | 54 VDC | 54 VDC |
Overcharge Protection | 63 VDC | 63 VDC |
SOLAR CHARGER & AC CHARGER | ||
Solar Charger type | MPPT | MPPT |
Maximum PV Array Power | 4500W | 4000W |
MPPT Range @ Operating Voltage | 120 ~ 430 VDC | 120~450VDC |
Maximum PV Array Open Circuit Voltage | 450 VDC | 500 VDC |
Maxmum Solar Charge Current | 80A | 80A |
Maximum AC Charge Current | 80A | 60A |
Maximum Charge Current | 80A | 80A |
PHYSICAL | ||
Dimension, D X W X H (mm) | 120 x 295 x468 | 100 x 300 x 440 |
Net Weight (kgs) | 11.0 | 10 |
Communication Interface | USB and RS232+Dry contact | USB/RS232 |
OPERATING ENVIRONMENT | ||
Humidity | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature | -10℃ to 50℃ | -10℃ to 50℃ |
Storage Temperature | -15℃ to 60℃ | -15℃ to 60℃ |
Solar Panel Configuration – Example
Here, we recommend the wiring connection of solar panels with power rating from 250W to 315W
The minimum requirement of solar panels is 4 in series for the 5kW inverters with MPPT window 120-450V.
Minimum Power: 1 String of 4 panels in series (4 panels).
Full Power 2 string of 7 panels in series (14 Panels)
The above number is only a suggestion, other arrangements are also possible