In this brief article we put together the key characteristics of two very popular solar inverters / chargers. The Conversol MKS II (2nd generation) is compared with the VMII 5kW off-grid inverter. Both devices output a pure sinewave voltage of 230VAC with selectable charging current from 10Amp to 80Amp. Voltacon integrated the latest MPPT algorithm on each unit with 99% efficiency. Technically that means a more accurate tracking of the PV power at any time with minium loss of power less than 1%.
| MODEL | Conversol MKS II 5000-48 | Conversol VM II 5000-48 |
| Rated Power | 5000VA/5000W | 5000VA/5000W |
| Part No | 0610877900831 | 0610877900916 |
| Parallel Capability | YES, 9 units | No |
| Parallel Part Number | 31-010245-00G | N/A |
| Antitrust-Kit | No | YES |
| INPUT | ||
| Voltage | 230 VAC | 230 VAC |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) | 170-280 VAC (For Personal Computers) |
| 90-280 VAC (For Home Appliances) | 90-280 VAC (For Home Appliances) | |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | 50 Hz/60 Hz (Auto sensing) |
| OUTPUT | ||
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | 230VAC ± 5% |
| Overload capacity | 5s@≥150% load; 10s@110%~150% load; 100ms @ ≥200% load |
5s@≥150% load; 10s@110%~150% load; 100ms @ ≥200% load |
| Efficiency (Peak) | 90% | 90% |
| Transfer Time | 10 ms (For Personal Computers) 20 ms (For Home Appliances) |
10 ms (For Personal Computers) 20 ms (For Home Appliances) |
| Waveform | Pure sine wave | Pure sine wave |
| BATTERY | ||
| Battery Voltage | 48 VDC | 48 VDC |
| Floating Charge Voltage | 54 VDC | 54 VDC |
| Overcharge Protection | 63 VDC | 63 VDC |
| SOLAR CHARGER & AC CHARGER | ||
| Solar Charger type | MPPT | MPPT |
| Maximum PV Array Power | 4500W | 4000W |
| MPPT Range @ Operating Voltage | 120 ~ 430 VDC | 120~450VDC |
| Maximum PV Array Open Circuit Voltage | 450 VDC | 500 VDC |
| Maxmum Solar Charge Current | 80A | 80A |
| Maximum AC Charge Current | 80A | 60A |
| Maximum Charge Current | 80A | 80A |
| PHYSICAL | ||
| Dimension, D X W X H (mm) | 120 x 295 x468 | 100 x 300 x 440 |
| Net Weight (kgs) | 11.0 | 10 |
| Communication Interface | USB and RS232+Dry contact | USB/RS232 |
| OPERATING ENVIRONMENT | ||
| Humidity | 5% to 95% Relative Humidity(Non-condensing) | 5% to 95% Relative Humidity(Non-condensing) |
| Operating Temperature | -10℃ to 50℃ | -10℃ to 50℃ |
| Storage Temperature | -15℃ to 60℃ | -15℃ to 60℃ |
![]()

Full Spec 5kW Conversol MKS II 5000-48 Inverter charger with 450VDC and parallel function with communication cards. Up to 9 units will work together

Ultimate solution for high power solar phovoltaic arrays with maximum open circuit voltage 500Vdc. Conversol VM II 5000-48
Solar Panel Configuration – Example
Here, we recommend the wiring connection of solar panels with power rating from 250W to 315W
The minimum requirement of solar panels is 4 in series for the 5kW inverters with MPPT window 120-450V.
Minimum Power: 1 String of 4 panels in series (4 panels).
Full Power 2 string of 7 panels in series (14 Panels)
The above number is only a suggestion, other arrangements are also possible
The inverters are available from our official online solar shops please visit https://voltaconsolar.com
We also offer free of any obligation design services for off-grid solar photovoltaic systems.